  • Hf-710C pet infusion pump

Hf-710C pet infusion pump

HF-710C pet-specific infusion pump technical parametersInfusion modeFour infusion modes: ml/hour, total volume/time, drop/minute and drug libraryInfusion set specificationsSpecial or standard disposab

Essential Details

HF-710C pet-specific infusion pump technical parameters

Infusion mode

Four infusion modes: ml/hour, total volume/time, drop/minute and drug library

Infusion set specifications

Special or standard disposable infusion set (20 and 60 drops/ml, diameter 3.4~4.5mm)

Flow rate setting range1.0mlh~ 1200mlh
flow rate increment1.0-99.9mlh in 0.1ml/h increments: 100-1200m/h in 1m/h increments

Infusion flow rate accuracy

≤±5% (standard infusion set after calibration)

Preset setting range

0.1~9999.9 ml

Cumulative display range0~9999.9 ml
time setting1 minute ~> 99 hours 00 minutes
Quick sort speed

600m/h, the well shows fast displacement

KVO flow rate

1.0ml/h- 5m/h. Adjustable

Key Function

All digital keys

BOLUS function

With the first (pill) dose function, the flow rate can be set arbitrarily

night function

Start the night mode, no operation for 5 minutes after the infusion, the screen will automatically reduce the brightness

Blocking pressure detectionDedicated upper and lower pipeline dual pressure sensor detection, detection range: 40KPa~ 130KPa, 10-level adjustable sensitivity, dynamic display of pressure value changes
volumeButton volume and alarm volume are adjustable in 10 steps
Anti-motor reverse functionAnti-motor reversal device, real-time monitoring of the running direction of the stepper motor, to prevent reverse pumping
Machine self-check functionPower-on self-test and real-time self-test during infusion
Alarm promptAir bubbles, upper line blockage, lower line blockage, door open, infusion complete, pause timeout, low battery, battery drain, battery drop, AC disconnection, motor error, pump error, infusion parameter error, system error, Communication error, infusion set not calibrated, air bubble sensor error
show3.2-inch high-definition bright blue LCD dot matrix display
AC powerAC: 100V~240V, 50Hz/60Hz, Maximum power consumption: 25VA
Built-in batteryRechargeable lithium battery, DCII.IV. 3000mnAh; speed not more than 25ml/h, working time: ≥10 hours, real-time detection of battery power and display
Use environmental conditions+5C~+40C. Relative humidity: 20%~90%, Atmospheric pressure: 70 J06KPaH
transport and storage conditions-20C~+S5C. Relative humidity: 10%-90%, Atmospheric pressure: 70 H0KPgX )
safety classElectrical Class 1 with Functional Earth, Type CF, IPX3 Equipment
Dimensions and weightSize: 145mmX 150mmX 200mm; Weight: 1.7kg 
Infusion set management and calibrationWith multi-brand infusion set input and storage functions, can be selected arbitrarily after calibration
Bubble detection

Ultrasonic bubble detection, can detect bubbles ≥ 50ul, and the sensitivity of bubbles from 50ul to 300ul can be adjusted in 10 levels